D2SRS™|Stereotactic Radiotherapy System

D2SRS™

Stereotactic Radiotherapy System

A next-generation precision radiotherapy solution designed for stereotactic treatment of intracranial lesions and small tumors throughout the body. The system integrates a high-resolution Micro-MLC and motorized conical collimators, providing excellent targeting accuracy and dose conformity for Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). Through precise beam shaping and dose delivery, TiGRT D2SRS™ addresses the stringent accuracy requirements of high-dose stereotactic irradiation. It can be widely applied to the stereotactic treatment of intracranial lesions and tumors such as lung, liver, prostate, and pancreatic cancers.

marketing@linatech.com.cn

Product Superiority

雷泰医疗

Micro-MLC System

Equipped with a 2.5 mm high-resolution Micro-MLC, the system enables fine beam shaping and precise dose modulation for small targets and high-precision stereotactic radiotherapy.

雷泰医疗

Integrated Conical Collimation

Integrated 4–35 mm motorized conical collimators with 2D auto-centering capability provide flexible and precise beam shaping for a wide range of small-field stereotactic treatment applications.

雷泰医疗

Intelligent Automated Switching

The system accommodates both the Micro-MLC and conical collimators and enables intelligent, fully automated switching between the two beam-shaping modalities according to treatment requirements. No manual intervention is required, simplifying the workflow and improving treatment efficiency.

Integrated 2D Auto-Centering Conical Collimator

The system integrates 2 mm ultra-thin leaves at the treatment isocenter and nine motorized conical collimators for flexible small-field treatment.
The conical collimators are directly integrated within the MLC assembly, allowing the MLC and conical collimators to be operated independently according to clinical requirements.
The collimator assembly can be adjusted in both the lateral and longitudinal directions with one-click control. The system enables real-time verification and correction of the alignment between each cone center and the beam axis directly from the treatment control room, helping maintain accurate beam-to-isocenter alignment.

Related Products

Venus Linac

View Details

D2SRS™ Stereotactic Radiotherapy System

View Details

TiGRT-TPS Radiotherapy Treatment Planning System

View Details

customer service hotline

+86 10 6788 8916

关注我们

Scan to follow the official account

Get the latest information about Leata

hot line:+86 10 67888916

time:8:00 - 18:00